Condensing temperature output | +4℃±0.2℃ (factory setting |
Sampler gas dew point output | ≤5.0℃ at 25℃ with gas flow 2NL/min |
Working temperature | +2℃ to +45℃ |
Sampling gas dealing ability | 250NL/h |
Sampler gas dew point output (Max) | ≤+80℃ |
Sampler gas temperature | ≤+180℃ |
Sampler gas pressure | ≤3bar |
Different pressure | ≤3mbar |
Inlet connector | OD6mm |
Outlet connector | OD6mm |
High temperature alarming | ≥+8 ℃ alarming |
Low temperature alarming | ≤+2℃ alarming |
Warm up | ≤30min |
Power supply | 220V AC 50Hz |
Power consumption | 150W |
Dimension | 240W*215H*180Dmm |
Weight | 7kg |
EC122 semiconductor condenser is widely used inrapid dehydration and minimizes water-soluble components of gas lost, for online gas analysis instruments, providing a complete sample drying gas. It can work in ambient temperature of +2℃ to +45 ℃.
Condensing temperature output | +4℃±0.2℃ (factory setting |
Sampler gas dew point output | ≤5.0℃ at 25℃ with gas flow 2NL/min |
Working temperature | +2℃ to +45℃ |
Sampling gas dealing ability | 250NL/h |
Sampler gas dew point output (Max) | ≤+80℃ |
Sampler gas temperature | ≤+180℃ |
Sampler gas pressure | ≤3bar |
Different pressure | ≤3mbar |
Inlet connector | OD6mm |
Outlet connector | OD6mm |
High temperature alarming | ≥+8 ℃ alarming |
Low temperature alarming | ≤+2℃ alarming |
Warm up | ≤30min |
Power supply | 220V AC 50Hz |
Power consumption | 150W |
Dimension | 240W*215H*180Dmm |
Weight | 7kg |
Measuring carbon dioxide (CO2) is important for understanding the role it plays in the environment and its effect on climate change. CO2 is a major component of Earth’s atmosphere, and it traps heat like a blanket, causing global temperatures to rise. Too m uch CO2 can lead to drastic changes in our weather patterns and ecosystems, so monitoring its levels is essential for predicting future climate conditions. Additionally, measuring CO2 can help us better understand our impact on the environment and make informed decisions about how to reduce emissions and slow down down down down down global warming. By analyzing CO2 data over time, we can develop strategies to mitigate the effects of climate change and ensure a sustainable future.
Before industrialization, the global average annual atmospheric carbon dioxide concentration was 278ppm (1ppm is one part per million). In 2012, the global annual average atmospheric carbon dioxide concentration was 393.1ppm. By April 2014 , the monthly average carbon dioxide concentration in the northern hemisphere atmosphere exceeded 400ppm for the first time. . 2. Global climate warming, the continuous aggravation of the atmospheric greenhouse effect leads to global climate warming, resulting in a series of global climate problems that cannot be predicted by today’s science. According to the International Climate Change Economics Report, if human beings maintain the current way of life, by 2100, there will be a 50% chance that the global average temperature will rise by 4°C.
Copyright © 2023 esegas.com, All rights reserved.
Enviro Solutions Technology Co., Ltd (ESE Technology) is a gas analyzer manufacturer and leading provider in ODM/OEM services for gas analysis systems used by international famous brands.
We will contact you within 1 working day, please pay attention to the email with the suffix “[email protected]”.
We’ll send you the catalog as soon as you submit your email