Introduction
The ESEGAS ESE-LASER-100P Portable TDLAS Gas Analyzer is designed for selective on-site measurement of trace gases in industrial emissions and process gas streams. Using Tunable Diode Laser Absorption Spectroscopy (TDLAS), it supports measurement of NH₃, HCl, and HF through their characteristic laser absorption wavelengths. The portable system integrates a gas analyzer, heated sampling line, and extendable sampling probe to maintain suitable sample conditions during field measurements. Its high selectivity, fast response, and resistance to background gas interference make it suitable for emission inspections, equipment commissioning, troubleshooting, and industrial gas concentration surveys.
Measured Gas: NH₃ | HCl | HF
Technology: TDLAS
| Performance parameters | |||||||||||||
| Gas | Range | Resolution | Repeatability | Linearity | Response time | Drift | |||||||
| HCl | 0-100 mg/m3 | 0.1 mg/m3 | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
| HF | 0-100 mg/m3 | 0.1 mg/m3 | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
| NH3 | 0-100 ppm | 0.1 ppm | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
| Electrical parameters | |||||||||||||
| Warm up time | 60min | Digital output | RS232 | Data storage | Configure USB 2.0 interface | ||||||||
| Power supply | AC200-240V/ 47-63Hz | power | <0.8kW | ||||||||||
| Environmental parameters | |||||||||||||
| Sample gas humidity | 0-99% RH | Sample gas temperature | ≤600℃ | Sample gas pressure | Atmospheric pressure ±5kPa | ||||||||
| Storage humidity | 0-99% RH | Ambient temperature | -10~55℃ | Environmental pressure | 70kPa-120kPa | ||||||||
| Sampling flow | 2-3L/min | Protection level | IP44 | ||||||||||
| Mechanical parameters | |||||||||||||
| Analyzer dimensions | 210 (W) * 460 (L) * 340 (H) mm | weight | 18kg | ||||||||||
| Box dimensions | 500 (W) * 600 (L) * 150 (H) mm | weight | 7.5kg | ||||||||||
| Sample gas inlet joint specifications | Ø6 Stainless steel ferrule joint | Sample gas outlet connector specifications | Ø6PVDF connector | ||||||||||
☑ Full-temperature high-temperature heat extraction method is adopted, which is not limited by on-site working conditions, wide applicability, and simple to use and maintain;
☑ Using TDLAS high-resolution spectroscopy technology, it can be measured without interference from other gases, which can effectively reduce the influence of dust or background gas. This feature has obvious advantages compared with other analytical methods.
☑ Laser optical spectrum analysis has the advantages of fast response and high sensitivity. In practical applications, the resolution can reach 0.1ppm, which can meet the accuracy requirements of industrial instrument gas component detection.

The portable laser gas analyzer applications include:
☑ Process control:
SCR, incineration &combustion processes.
☑ Emission monitoring:
Power generation, engine development, waste incineration fuels.
☑ Chemical engineering:
Production control & monitoring leak detection, refrigeration, toxic gases
☑ Others:
Environmental comparison and acceptance, emergency detection, instrument calibration, self-examination, laboratory gas detection and analysis of multi-level environmental monitoring stations, third-party testing institutions, fixed pollution sources and gaseous pollutants, coal-fired power plants, gas power plants, cement plants, steel plants, etc.
ESE-LASER-100P The portable laser gas analyzer is composed of a gas analyzer main unit, an integrated heat tracing line, and an extendable probe. The analyzer is suitable for gas emission detection in many industrial fields, such as coal-fired power plants, aluminum plants, steel plants, smelters, garbage power stations, cement plants and chemical plants, and glass plants.
A portable laser gas analyzer is a compact and handheld instrument that utilizes laser-based technology to measure and analyze the composition and concentration of gases in various applications. These analyzers are designed for on-site or field measurements, offering flexibility and portability for gas analysis in different locations or environments. Benifits include:
A portable TDLAS gas analyzer is a field measurement instrument that uses Tunable Diode Laser Absorption Spectroscopy to selectively measure target gases at industrial sites.
Depending on the laser configuration, ESEGAS portable TDLAS analyzers can measure NH₃, HCl, and HF.
It emits laser light at a wavelength absorbed by the target gas. The analyzer evaluates the absorption signal to determine gas concentration.
TDLAS provides high gas selectivity, fast response, and low detection limits. Its portable configuration allows engineers to perform measurements at different industrial sampling points.
Yes. A suitably configured portable NH₃ TDLAS analyzer can measure ammonia concentrations around SCR and SNCR systems to support denitrification performance testing.
Portable TDLAS analyzers are intended for temporary field testing and troubleshooting. Online TDLAS analyzers are installed at fixed locations for continuous industrial monitoring.
The analyzer main unit adopts Tunable Diode Laser Absorption Spectroscopy (TDLAS), which can be used to detect the concentration of specific gas components in the gas to be tested, including NH3, H2S, HCL, HF, CO, etc. The analyzer has the characteristics of high sensitivity, fast response, no interference from background gas, non-contact optical measurement, etc. It provides a reliable guarantee for real-time accurate reflection of gas concentration.
| Performance parameters | |||||||||||||
| Gas | Range | Resolution | Repeatability | Linearity | Response time | Drift | |||||||
| HCl | 0-100 mg/m3 | 0.1 mg/m3 | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
| HF | 0-100 mg/m3 | 0.1 mg/m3 | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
| NH3 | 0-100 ppm | 0.1 ppm | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
| Electrical parameters | |||||||||||||
| Warm up time | 60min | Digital output | RS232 | Data storage | Configure USB 2.0 interface | ||||||||
| Power supply | AC200-240V/
47-63Hz |
power | <0.8kW | ||||||||||
| Environmental parameters | |||||||||||||
| Sample gas humidity | 0-99% RH | Sample gas temperature | ≤600℃ | Sample gas pressure | Atmospheric pressure ±5kPa | ||||||||
| Storage humidity | 0-99% RH | Ambient temperature | -10~55℃ | Environmental pressure | 70kPa-120kPa | ||||||||
| Sampling flow | 2-3L/min | Protection level | IP44 | ||||||||||
| Mechanical parameters | |||||||||||||
| Analyzer dimensions | 210 (W) * 460 (L) * 340 (H) mm | weight | 18kg | ||||||||||
| Box dimensions | 500 (W) * 600 (L) * 150 (H) mm | weight | 7.5kg | ||||||||||
| Sample gas inlet joint specifications | Ø6 Stainless steel ferrule joint | Sample gas outlet connector specifications | Ø6PVDF connector | ||||||||||