Introduction
The ESEGAS ESE-GH-2080P Greenhouse Gas Analyzer is designed for portable measurement of major greenhouse gases in industrial emissions and environmental monitoring applications. Combining Gas Filter Correlation (GFC), NDIR, and TDLAS technologies, the analyzer provides reliable gas concentration data for greenhouse gas emission assessments, methane leak investigations, environmental research, and industrial process monitoring. Its integrated sampling and data recording functions make it suitable for mobile field measurements and laboratory applications.
Measured Gas: CO₂ | CH₄ | N₂O | Optional CO & O₂
Technology: NDIR-GFC | TDLAS
Configurations: Portable
| Model | ESE-GH-2080P Portable Greenhhouse Gas Analyzer |
| Measuring principle | Infrared absorption (NDIR) |
| measuring gas | N2O: NDIR-GFC, CO2: NDIR, CH4: TDLAS |
| Measurement range | CH4: 0-100ppm. CO2: 0-2000ppm. N2O: 0-100ppm. |
| Accuracy | CH4: ±1%FS. CO2: ±2%FS. N2O: ±1%FS. |
| Resolution | 0.01% vol |
| Repeatability | ≤2% |
| Optimal Flow Rate | 0.7-1.2 L/min |
| Inlet pressure | 2-50kPa |
| Response Time | T90 < 15s |
| Sample Gas Condition | Dust-free, dry, oil-free |
| Output Interface | USB |
| Display | 5-inch TFT LCD touchscreen |
| Power Supply | 220 V AC |
| Power Consumption | 100 W |
| Weight | 10 kg |
| Operating Temperature | 0 – 45°C |
| Standard Configuration | Built-in imported sampling pump Integrated gas pretreatment system Internal printer Self-diagnostic system for sensor status monitoring |
Applications of Portable Greenhouse Gas Analyzer includes:
Industrial Emission Monitoring
Monitor greenhouse gas emissions from fixed sources in:
Supports emission verification, process optimization, and environmental compliance.
Environmental Monitoring
Ideal for field-based greenhouse gas assessments, including:
Provides fast, real-time data for air quality and greenhouse gas investigations.
Mobile Monitoring
Suitable for vehicle-mounted monitoring systems used for:
Enables efficient monitoring across wide geographic areas.
Research & Laboratory Applications
Widely used by:
Supports greenhouse gas studies, soil flux measurements, and atmospheric research with laboratory-grade accuracy in the field.
The ESE-GH-2080P Portable Greenhouse Gas Analyzer is designed for high-precision measurement of greenhouse gases in industrial emissions and environmental monitoring applications. Utilizing advanced GFC (Gas Filter Correlation) infrared technology and TDLAS (Tunable Diode Laser Absorption Spectroscopy), combined with modern digital signal processing, the analyzer enables simultaneous, real-time measurement of key greenhouse gases such as: CH4 (Methane), N2O (Nitrous) Oxide), and CO2 (Carbon Dioxide).
Optional sensors for CO and O2 are also available for expanded monitoring capabilities.
A greenhouse gas analyzer is an instrument that measures the concentrations of gases such as carbon dioxide (CO₂), methane (CH₄), and nitrous oxide (N₂O). It provides measurement data for industrial emission assessments, environmental monitoring, process control, and greenhouse gas research. The appropriate analyzer depends on the target gases, expected concentrations, and measurement conditions.
The ESEGAS ESE-GH-2080P greenhouse gas analyzer measures CO₂, CH₄, and N₂O simultaneously. Optional CO and O₂ measurement channels are also listed for expanded gas analysis. Gas combinations and measurement ranges should be confirmed when selecting the instrument. CO and O₂ measurements provide additional process information; they should not be classified as direct greenhouse gas measurements.
An optical greenhouse gas analyzer measures how much infrared light a gas sample absorbs at characteristic wavelengths. The instrument uses this absorption signal to calculate gas concentration. Depending on the configuration, measurement technologies can include non-dispersive infrared spectroscopy (NDIR), gas filter correlation (GFC), and tunable diode laser absorption spectroscopy (TDLAS).
Greenhouse gas analyzers are used to investigate emissions from industrial facilities, landfills, wastewater treatment plants, agricultural activities, and energy production. They also support laboratory experiments and environmental research. Each application requires suitable measurement sensitivity and sampling equipment, particularly when measuring small concentration changes or gases in complex sample backgrounds.
Yes. A suitably configured multi-component greenhouse gas analyzer can measure CO₂, CH₄, and N₂O simultaneously from one sample stream. This allows users to compare concentration trends across the three gases during the same measurement period. The ESEGAS ESE-GH-2080P is listed with simultaneous measurement of these components.
The required measurement range and detection limit depend on the expected concentration and the smallest change you need to detect. Industrial source measurements and atmospheric background studies have different requirements. Atmospheric CH₄ and N₂O occur at much lower concentrations than CO₂, making sensitivity especially important. Compare detection limit, precision, accuracy, and drift; display resolution alone does not establish measurement capability.
Extractive greenhouse gas analyzers may need sample pretreatment to meet their inlet requirements. The ESEGAS ESE-GH-2080P specifies a dry, dust-free, and oil-free sample. Depending on the source, the sampling system may require filtration, moisture management, and pressure or flow control. Sample conditioning must preserve the target gas concentrations and establish a consistent wet or dry measurement basis.
A greenhouse gas analyzer is typically checked using suitable zero gas and certified reference gas mixtures with known concentrations. Follow the instrument manual for gas composition, inlet conditions, calibration steps, and adjustment procedures. The checking frequency should reflect instrument stability, operating conditions, and the project’s quality requirements. Keep calibration records to track measurement performance over time.
A compatible greenhouse gas analyzer can provide concentration measurements for a chamber-based soil flux system. Calculating flux also requires the concentration change over time, effective chamber volume, soil surface area, temperature, and pressure. Analyzer sensitivity, response time, sample flow, and chamber mixing must suit the experiment. Concentration readings alone are insufficient to determine soil greenhouse gas flux.
Provide the target gases, expected concentration ranges, required detection limits and accuracy, and application details. Include sample temperature, pressure, humidity, dust or oil content, measurement duration, and installation environment. For an ESEGAS quotation, also specify whether you need portable measurements, sampling accessories, data logging, communication interfaces, or integration with an existing monitoring system.
| Model | ESE-GH-2080P Portable Greenhhouse Gas Analyzer |
| Measuring principle | Infrared absorption (NDIR) |
| measuring gas | N2O: NDIR-GFC, CO2: NDIR, CH4: TDLAS |
| Measurement range | CH4: 0-100ppm. CO2: 0-2000ppm. N2O: 0-100ppm. |
| Accuracy | CH4: ±1%FS. CO2: ±2%FS. N2O: ±1%FS. |
| Resolution | 0.01% vol |
| Repeatability | ≤2% |
| Optimal Flow Rate | 0.7-1.2 L/min |
| Inlet pressure | 2-50kPa |
| Response Time | T90 < 15s |
| Sample Gas Condition | Dust-free, dry, oil-free |
| Output Interface | USB |
| Display | 5-inch TFT LCD touchscreen |
| Power Supply | 220 V AC |
| Power Consumption | 100 W |
| Weight | 10 kg |
| Operating Temperature | 0 – 45°C |
| Standard Configuration | Built-in imported sampling pump
Integrated gas pretreatment system Internal printer Self-diagnostic system for sensor status monitoring |
We will contact you within 1 working day, please pay attention to the email with the suffix “[email protected]” .