HCL Analysis in Waste Generation Application

HCL Analysis in Waste Generation Application

Picture of Sharon Ye
Sharon Ye

Technical Sales - Energy & Environment

Content

HCL laser on-line monitoring system

 

Waste generation application Customer Name: International energy waste incineration power generation 

 

Running Time: 2017-10 

 

Field technology: natural gas is used as fuel, urban waste is incineration at high temperature. After burning, the tail gas is removed by denitrification, desulfurization and dedusting process

 

tdl gas analysis system 2

 

hcl gas analysis 1

 

 Installation position: exhaust flue gas

 

Measurement range: 0-100mg/m3

 

The above is the change trend curve of SO2 and HCL in the same period. From the map, HCL and SO2 have similar trend of change.  which both have a good response to the change of deacidification process. 

 

 

HCL laser on-line monitoring system — medical waste in Yongkang Customer Name: Medical waste in Yongkang, Anhui 

 

Running Time: 2016-12 

 

Field technology: the site is mainly used for the incineration treatment of medical waste, the exhaust emission is first deacidification treatment, the deacidification agent is NaHO, and then dedusting and discharging. The limit of emission limit is HCL 100mg/m3 

 

Installation position: the equipment is installed in the middle of the chimney, about 10m high, and the diameter of the chimney is 0.5m 

 

Measurement range: 0-300mg/m3